Base Consumption and Peak Consumption: Difference between revisions

 
(One intermediate revision by the same user not shown)
Line 9: Line 9:
==Determining base consumption and peak consumption==
==Determining base consumption and peak consumption==


Without using specific devices to measure instant load, we can still determine two important scenarios, estimating the base load and peak load through base and peak consumption over a specified amount of time. Measurement devices for electrical energy are cheaply available and can help in making base and peak load determinations.
Without using specific devices to measure instant load, we can still determine two important scenarios, estimating the base load and peak load through base and peak consumption over a specified amount of time. Measurement devices for electrical energy are cheaply available and can help in making base and peak load evaluations.


The energy load at a specific moment in time can be indirectly determined by having frequent meter readouts. For instance, reading the meter index with most devices turned on at a specific time and then after 30 minutes or an hour can give a rough estimation of the peak consumption in that timeframe. This situation should not be considered typical but as a clear indication of an extreme case that can occur.
The energy load at a specific moment in time can be indirectly determined by having frequent meter readouts. For instance, reading the meter index with most devices turned on at a specific time and then after 30 minutes or an hour can give a rough estimation of the peak consumption in that timeframe. This situation should not be considered typical but as a clear indication of an extreme case that can occur.
Line 30: Line 30:
|-
|-
|}
|}
Note: The base consumption is computed as the difference between a night meter readout and the following morning one, and the peak consumption as the difference between a morning and a night reading on the same day. The base load is considered to be at night, because the consumption is lower in this time period, although the length of time between measurements is roughly the same.
Note: In this case, the base consumption is computed as the difference between a night meter readout and the following morning one, and the peak consumption as the difference between a morning and a night reading on the same day. The base load is considered to be at night, because the consumption is lower in this time period, although the length of time between measurements is roughly the same.


[[Category:Energy Conservation]]