Standard Metal Hallide Lamp for indoor and outdoor lighting with 250W and 400W (E40 base), clear tubular bulb
Very High colour rendering T8 fluorescent linear lamps TL-D type 90 Graphica


== Features ==
== Features ==
*Clear tubular outer bulb
*Special Halophosphate based coating
*Internal high pressure quartz discharge tube
*G3 bi-pin base
*E40 base
*Color rendering index Ra of 95
*Color rendering index Ra of 65
*Typical lifetime of 20.000 to 24.000 hours
*Typical lifetime of 20.000 to 24.000 hours
*Luminous efficacy of 84 to 89 lumens/watt
*Luminous efficacy of 61 to 93 lumens/watt
*Cool white or daylight colour designation (4500 or 6700 K colour temperature)
*Two white appearances (5300 and 6500 K colour temperature)
*Horizontal operating position
*Universal operating position


== Lamp control gear ==
== Lamp control gear ==
*Requires external gear (similar to mercury vapour lamps) and appropriate wiring:
*Requires external gear and appropriate wiring:
** Philips BHL or compatible reactive inductive ballast with matching power rating
** Compatible reactive inductive ballast with matching power rating and starter
** Philips SI or compatible parallel ignitor for 5000 Volt pulses
** Compatible high-frequency electronic ballast with preheating (preferably)
** May require power factor correction capacitor for balancing line load
** May require power factor correction capacitor for reactive ballasts


|style="vertical-align:top" |
|style="vertical-align:top" |
[[Image:Philips HPI-T 1000W.jpg|Philips HPI-T 1000W]]
[[Image:Philips TL-D 36W.jpg|Philips TL-D 36W]]
|}
|}
</div>
</div>


== Best retro purpose ==
== Best retro purpose ==
Metal Hallide lamps are still widely used on commercial, industrial and architectural lighting but in these applications LED lamps are quickly replacing them due to much better performance, lower energy consumption and easy servicing. Light appearance is coll white or daylight, depending on lamp model, with good colour reproduction and low ultraviolet emission. The lamp can be used indoors as well as outdoors, when intense lighting is required as most surrounding look quite pleasing being light with new lamps.
Flourescent lamps are the most popular and widely used lighting source. Still widely used in most indoor environments due to their high efficiency and very good colour reproduction, flourescent lamp stocks and availability is still high. Millions of these lamps have been produced worldwide for decades. They are clearly suited for indoor lighting especially when paired with an electronic ballast that eliminates flicker and also increases system efficiency. Due to the great variety of lamps, there are some suggestions for use. Most flourescent lamps operate well at 25 degrees Celsius ambient temperature and have very low light output in freezing or below freezing environments but hot environments also reduce efficiency.


Exterior lighting is a good application as most gardens and outside areas are well showcased. The lamp themselves do release some heat meaning that closed fixtures are not well suited if not specifically built for this purpose. Care should be taken when using these metal-hallide lamps as they are sensitive to the operating position especially when inside enclosed fixtures. Improper heating of lamp can destroy it prematurely and present a safety hazard so special precaution should be exercised. While lamp warm up time is low, with the lamp achieving high output quite quickly, they are slow to restart, 10 minutes pauses not being uncommon.
90 Graphica lamps were specialist items, high-end products that had a highly accurate colour reproduction. They were used in environments such as the printing and publishing business were comparisons and proofing of printed materials was required. These lamps had very low efficiency compared with other flourescent lamps but had a almost unique abilities for professional environments. While these lamps can be used in interior lighting and they showcase everything as is they were light by the sun on a clear day, their lower efficiency, slightly higher luminous flux loss due to aging and limited colour appearance selection make them quite unsuitable for general lighting. 90 Graphica lamps have been manufactured in very low quantities which means that stocks are scarce.
 
While both high pressure mercury vapour and high pressure sodium gear and fixtures can be used, the lamp works closer to designed parameters when used with inductive ballasts for mercury vapour lamps and a suitable ignitor added on the circuit as required. Compact, boxy symmetric and asymmetric fixtures were popularly. Clear lamps are well suited to high efficiency reflector fixtures while coated lamps work better in open luminaries or classic mercury vapour fixtures.  
 
With adequate care and good ventilation, HPI metal hallides can be used vertically, in a freestanding position as mercury vapour lamps but lifetime will be reduced. HPI-T lamps are much more sensitive to operating position. Lamps age differently and this means that a series of lamps may exhibit different colour intensity and light intensity depending on wear and group replacement should be considered to maintain uniformity. Just as well, lamps should be replaced as soon as light and colour uniformity is affected, as old lamps present a higher risk of catastrophic failure.


== Understanding manufacturer data ==  
== Understanding manufacturer data ==  
Line 49: Line 44:
! Designation !! Base !! Lamp wattage !! Luminous flux !! Colour appearance !! Colour Temperature !! Colour Rendering Index (Ra8) !! Life (to 50% failures)
! Designation !! Base !! Lamp wattage !! Luminous flux !! Colour appearance !! Colour Temperature !! Colour Rendering Index (Ra8) !! Life (to 50% failures)
|-
|-
| MASTER HPI-T Plus 250W/645 E40 SLV || E40 || 250 W || 20500 lm || Cool White || 4500 K || 65 || 20000 hours
| MASTER TL-D 90 Graphica 18W/950 SLV || G13 || 18 W || 950 lm || Daylight || 5300 K || 98 || 20000 hours
|-
|-
| MASTER HPI-T Plus 400W/645 E40 SLV || E40 || 400 W || 35000 lm || Cool White || 4500 K || 65 || 20000 hours
| MASTER TL-D 90 Graphica 18W/965 SLV || G13 || 18 W || 930 lm || Cool Daylight || 6500 K || 98 || 20000 hours
|-
|-
| HPI-T 1000W/645 E40 220V CRP || E40 || 1000 W || 85000 lm || Cool White || 4500 K || 65 || 24000 hours
| MASTER TL-D 90 Graphica 36W/950 SLV || G13 || 36 W || 2300 lm || Daylight || 5300 K || 98 || 20000 hours
|-
|-
| HPI-T 2000W/667 E40 220V CRP || E40 || 2000 W || 189000 lm || Cool White || 6700 K || 65 || 24000 hours
| MASTER TL-D 90 Graphica 36W/965 SLV || G13 || 36 W || 2100 lm || Cool Daylight || 6500 K || 98 || 20000 hours
|-
| MASTER TL-D 90 Graphica 58W/950 SLV || G13 || 58 W || 3650 lm || Daylight || 5300 K || 98 || 20000 hours
|-
| MASTER TL-D 90 Graphica 58W/965 SLV || G13 || 58 W || 3350 lm || Cool Daylight || 6500 K || 98 || 20000 hours
|-
|-
|}
|}
Notes: "MASTER" designation should point at better performing lamps but it is meaningless in this lamp range.


== Durability and Repair-ability ==
== Durability and Repair-ability ==
Generally, sodium vapour lamps were very durable and most modern products were released with even longer typical lifetimes. This is mainly due to the fact that the main market of street lighting pressured producers to cot servicing costs which means that reliability improvements were mandatory. Unfortunately, due to the way that almost all lamps are designed, they age in a different way compared with other light sources. Sodium slowly permeates the ceramic arc tube meaning that the lamp voltage raises as the lamp ages, making it harder to remain in stable operation after startup. This creates the well known on-and-off lamp cycles that repeats every couple of minutes, accelerating as the lamps is close to demise. Eventually, the lamp does not start but this happens after a long cycling and gear stress that might span over months or even a whole year.
Compared with modern LED lamps, sodium lamps compare favourably but they have a much poorer light output and require careful wiring. In most cases operational cost is lower as less powerful LED luminaries can be used since all useful light is directed downwards compared with the inefficient fixtures used on most sodium vapour lamps. Ballast and ignitors can survive tens of years if properly protected against direct rain or snow exposure. A complex circuitry means that lamp servicing is difficult and there are major risks due to improper wiring on servicing as large voltages may be present. 70, 100 and 150 watt lamps are very well built and they were highly popular. Ignitors can be potentially repaired but the lack of schematics means that they can be repaired only by experienced persons and are, thus, mostly discarded when not working.


== Greatest features & flaws ==
== Greatest features & flaws ==
Line 71: Line 65:
! Features !! Flaws  
! Features !! Flaws  
|-
|-
| High light output in very compact package || Serious glare risk
| Low glare risk, uniform lighting || Quite large lamps and fixtures
|-
|-
| High efficiency, long life, average colour rendering || Quite expensive lamps
| Moderate efficiency, long life, almost perfect colour rendering || Fragile construction
|-
|-
| Mostly omni-directional light || Sensitive to operating position and unbalanced wearing
| Mostly suited for directional light || Sensitive to operating temperature
|-
|-
| Quick lamp start || Slow restart, requires bulky, heavy, complex lamp gear
| Quick lamp start and restart, inexpensive || Requires lamp gear
|}
|}


== Review ==
== Review ==
These metal hallide lamps are better suited for outdoor lighting due to their high power rating and good colour reproduction. Long service lifetime is also another major feature of these HPI-T lamps. Large wattage fixtures were very popular especially for flood lighting with boxy, asymmetric or symmetric lighting patterns. The most popular power ratings were 250 and 400 Watts. The lamp itself fares well in terms of light output but the point light source nature of the lamp relegates it to accent or directional rather than general lighting.
The TL-D range was conceived as a complete portfolio which was quite well suited for any task. While commercial lighting was the most successful market, flourescent lamps were present also in residential and industrial environments and they were highly successful. 90 Graphica lamps were up-market products that catered to excellent colour reproduction. Until the advent of advanced LED lamps, flourescent lamps were unsurpassed in terms of efficiency and lighting comfort. The lamp's quick restart, good light stability even on conventional, magnetic gear, and reasonably simple wiring made them easy to service although the lamp bi-pin connection was prone to failure due to lamp's handling as well as normal wear, the system was reasonably easy to repair and failures were quite obvious. The only drawback of these upper market lamps ranges was a slightly higher price than typical TL-D standard lamps and sensitivity to operating temperatures, common to all flourescent lamps. This major drawback seriously limited outdoor applications.


Exterior lighting is a good application as most gardens and outside areas are well showcased. The lamps themselves do release some heat meaning that closed fixtures are not well suited if not specifically built for this purpose. Care should be taken when using these metal-hallide lamps as they are sensitive to the operating position especially when inside enclosed fixtures. Compact, boxy symmetric and asymmetric fixtures were popular. Improper heating of lamp can destroy it prematurely and present a safety hazard so special precaution should be exercised. Even if lamp warm up time is low, achieving high output quite quickly, they are slow to restart, 10 minutes pauses not being uncommon.
90 Graphica lamps were high-end lamps designed for requirements of niche markets. Their efficiency was much less important than strict adherence to product manufacturing control, stability, and accurate colour reproduction. These lamps are true state-of-the-art products for situations where proofing of printed or on-screen materials is paramount and they were very successful. This product line has existed for more than 20 years and perfectly suited demanding technical requirements but is less suited for home or office environments due to price and scarcity. Low light outputs relative to other lamp types and especially to the Super 80 line seriously limits appeal even if perfect colour reproduction is a major advantage. Keep in mind that no known light source was available until these and compatible lamps from other manufacturers reached a fantastic colour rendering index of 98. Although incandescent and high intensity discharge lamps can get close with filters and special lamp types to accurate daylight reproduction, 90 Graphica lamps are truly unique.


== Operation ==  
== Operation ==  
These lamps are somewhat better suited for frequent switching but starting is still a major stress. They need less than two minutes to reach maximum light output and less than that to restart after being turned off. The light colour and output changes from start-up to normal operation from white to orange. White light at startup and then greenish light midway to warm-up suggests mercury is also used on the lamp. This slightly improves colour rendering but affects slightly reduces lamp life while the ones that do no change colour are either new or do not use mercury at all have a yellower light appearance. Lamps without mercury are more difficult to start but they have longer lifetimes and slightly higher efficiency.
All lamps require the same lamp gear that can be either conventional, composed of a magnetic, reactive or inductive ballast placed in series with the lamp along with a starter that preheats the lamp's filament to ensure reliable starts and low lamp stress. An electronic lamp gear, preferably with preheating, can be used to increase light output, eliminate flicker and increase the lamp's service life. Note that some cheap electronic ballasts do not actually offer preheating and start instantly the lamp, reducing the lamp's useful life. Preheating of lamps is assumed if there is any mention of a 0.5second duration on the electronic ballast label or the word preheating. Most world manufacturers released electronic control gear and some products even allowed variable dimming using special protocols.  


The lamp requires a conventional or electro-magnetic gear of the same power output as the lamp, connected in series with a lamp and an ignitor that must be connected as is required in the circuit. Connecting the lamp directly to mains damages it instantly as there is no current limitation. Improper connection of the ignitor is also dangerous and proper care must be exerted during installation and servicing. A power factor capacitor that has a specific value might be used to correct the power factor and current requirements on the circuit. The lamp itself is not influenced by the presence or absence of this capacitor. When used sparingly in homes or some premises where not a lot of these lamps are located, power factor correction is not important but large industrial or commercial clients were required to maintain a specific power factor due to electricity distribution contracting.  
While a dimmed flourescent lamp is not as efficient as full power operation, there were and are some environments were such flexibility is appreciated. Note that starting and operating dimmed lamps is less reliable and the temperature balance and optimum operation conditions slightly deviate in these circumstances. Overpowering a lamp is possible but it is not advised. While Super 80 lamps are best suited for these circumstance that increase light output with some reduction in efficiency and service lamps, operation in such conditions stresses the lamp. Note that operating in cold environments, as a deviation from ideal conditions, reduces lamp current and power, making the lamp slightly unstable and dim.


== Suitability ==  
== Suitability ==  
HPI-T lamps are much more effective for flood lighting but they require specific fixtures and have higher surface temperature, making them more susceptible to damage when improperly handled. Chinese branded lamps are much worse in all performance and quality metrics with shorter useful life, worse colour reproduction and and efficiency as a proper, stable mix of hallides required huge research investment that was too costly for Chinese producers. The difference between HPI-T and HPI-T Plus is mostly attributed to the ability of using either a high pressure sodium or mercury vapour lamp gear with minimal impact on service life and light output.  
A major advantage of T8 or TL-D lamps, regardless of type, is their full compatibility with systems of similar power ratings that were used with T12 lamps along with full replacement capability of any lamp type at a specific wattage. This makes it possible to test and replace many lamps of a specific wattage even mix lamps in multi-lamp fixtures to create a desired effect. Compatibility of T12 and T8 lamps was very important in the past as new T8 lamps were more efficient and used less power while being fully capable to be retrofitted on old installations.


The best choice is, probably, the 250 watt lamps as larger powered lamps are too powerful for most purposes. This product was also cheaper as they were highly popular. Electro-magnetic ballasts or conventional gears are plentiful and can be used interchangeably with all manufactured lamps for a specific wattage and ignitors' performance is less critical as on high pressure sodium lamps. Lower rated power output gears can be used, but it is not recommended as colour reproduction and lamp lifetime will be reduced while higher powered ones damage the lamp due to over-stressing and is highly dangerous.
Closed as well as open fixtures are very well suited for any lamp type. In general, open fixtures are better suited for lamps operating in warmer indoor environments while enclosed fixtures are better suited for colder environments. Despite what any datasheet may suggest, deviating higher or lower than the set 30-35 degrees Celsius lamp temperature slightly reduces efficiency. 90 Graphica lamps are more sensitive to additional light losses due to internal coating's temperature variation.


Used lamp gears might work but old lamps are never desirable as they degrade much quicker than mercury vapour and sodium lamps. Rusted ballast may still operate but are a potential hazard while old, used lamps, may not have much useful life left and they may already exhibit some colour light emission issues. New old-stock lamps are the best choice, if available.
== History ==
Flourescent lamps were an evolution of clear mercury vapour lamps. Development followed two avenues to increase efficiency, low pressure mercury vapour discharge and high pressure mercury discharge. High pressure mercury discharge created more useful light but the same deficit of no red and orange light was present so the light was still unsatisfactory. Low pressure mercury discharge is very efficient but not in outputting visible light, it is on UV-light emission. This UV-light is useless if it cannot be converted to visible light.


== History ==
Flourescent powders were developed to convert UV-light into visible light. Some of these powders were capable of emitting light at some wavelengths, making specific colours to be cast around but they had to be quite ressistant to UV-light and efficient. This meant that some time passed until the advent of halophosphate based colours that made possible the first daylight T12 flourescent lamps, around late 1930s. This was a major achievement as such lamps had the capability of directly competing with incandescent lamps and offer better efficiency and longer life.
The lamp technology was an improvement of previously developed mercury vapour lamps. The potential for fluorescent powders was mostly exhausted by early 70s which meant that research concentrated on releasing better lamps that produced light directly from the discharge tube. This research was also carried previously but results were modest, as stable compounds with good colour reproduction were found to be quite aggressive and lead to short service life. Sodium, Scandium, Indium, Thallium were attempted as main elements that can offer a balanced light output but they required a specific balance of temperature and pressure to achieve best results. One major limitation was that certain compounds were costly or difficult to manufacture or mix in specific amounts, which meant that suitable results could not be found for many decades. In the late 70s and early 80s most major manufactures were able to center on specific technologies that reached good enough results for general lighting, with predictable performance.


The market for large lamps was important as there was an interest in using more energy efficient lamps when the early 1970s oil crises brought new challenges. High pressure mercury vapour lamps were efficient but their light was not white while improvements in high pressure mercury vapour lamps were not satisfactory. While metal hallide lamps were more expensive than mercury vapour lamps, the energy savings that were around 25 to 50% meant that this technology was attractive enough considering much improved colour reproduction despite shorter lifetime. The ability to run on mercury vapour gear and the ability to retrofit these fixtures was critical to market success while the ability to run on high pressure sodium lamps ensured improvements on other installations. These are the most important factors that ensured market success as metal hallide lamps required careful installation, operation and restocking.
Subsequent developments improved lamp life and created a wide variety of flourescent powders that cast white light with different colour appearances from warm and neutral to cold and daylight. Higher and lower power lamps were created and standardization established. The preferred lamp gear turned from incandescent ballasting or mixed light to magnetic or reactive ballasts, which improved system efficiency. In the late 1970s, following requirements for higher energy efficiency due to the world oil crisis of 1973, there were major advances in technology.


Of course, metal hallide lamps were always less successful than fluorescent lamps, especially when larger fixtures, especially indoors, were not an issue. Fluorescent lamps were easy to stock, replace, had a longer useful life and they offered custom light reproduction with great prospects for energy efficiency improvements. Lower power rating metal hallides were developed and marketed but they required specific fixtures that were able to withstand the possibility of a blown old arc tube and the high heat output and complex operating gear, along with worse flicker than fluorescent lamps. All this, along with a large price justified by complex manufacturing quality control, meant that fluorescent lamps were always more popular in most commercial and all residential applications.
The advent of high efficiency tri-band or tri-phosphorous lamps was the most important landmark. Successful development of flourescent powders that had peak UV to visible light conversion at blue, red, and green colours with peaks near the ideal wavelengths made it possible to release lamps with specific colour appearances. This high energy in light conversion was complemented by changes in the lamps gas's fill from argon to Krypton, reducing thermal losses with a slight increase in operating voltage and starting voltage. This was the market releases of the the highly successful T8 lamp, or TL-D lamp that dominated since the early 90s. Of course, up until this time there were improvements in cathodes design and electron emmissive coatings as well as other performance enhancing solutions but the release of the TL-D lamp was the most important moment.


LED lamps affected the most this expensive lamp and gear technology, as it quickly surpassed it in ease of use, much longer useful lifetimes, better colour reproduction and versatility in both indoor and outdoor applications. This means that the market for metal hallide lamps was quickly diminishing even quicker than high pressure sodium vapour or even the older mercury vapour lamps, both surviving longer due to lower lamp replacement costs.
Production of specialist lamps started in the 1950s with coloured lamps but also expanded to include De Luxe and specific lamps that would cater for many purposes. De Luxe lamps were an improvement of standard lamps in terms of colour reproduction but was less efficient and had shorter service life due to coatings that were less stable in time than standard lamps. Graphica lamps were a slight adaptation of previously developed phosphorus to TL-D lamps and their gas's fill and some experimentation in improving other aspects of operation to achieve better performance.


== Manufacturing specificities ==
== Manufacturing specificities ==
Most manufacturers have been releasing lamps for many decades and constantly improved technology so that lamps had a stabler, predictable lifetime and slightly improved colour stability due to manufacturing progress. Lamps produced in the 70s and early 80s are probably not commonly found today. In the 90s and early 2000 Philips was manufacturing lamps in Holland and other countries, while in the last years they were doing the same thing in China. Quality was not severely affected as manufacturing quality was maintained and applications were demanding, used in wealthier countries. It should be noted that there are larger differences between compatible lamps released by Osram, General Electric or other major manufacturers as each of them settled on slightly different chemistry with different reliability and performance.
Philips flourescent lamps had very good manufacturing tolerances and the lamp's construction along with flourescent powder quality made reliable, predictable operation entirely ensured. Other world manufacturers were capable of similar performance. However, some slight differences were noticeable. For instance, Philips had slightly less powerful red phosphorus than Osram, which means that entirely equivalent lamps from both manufacturers had slightly different colour appearance. On the other side, Chinese branded lamps were much inferior in terms of flourescent powder quality and colour reproduction as well as efficiency and service life.
 
Products manufactured by Philips were similar to General Electric and Osram, with a quality and consistency much above some East-European manufacturers in terms of colour rendering, light output and life. However, Philips was manufacturing lamps with longer lifetimes but poorer colour reproduction than some Osram ones, especially on standard metal hallide lamps. Philips lamps were also much more popular and are easier to find.


{{footnotes|
{{footnotes|

Latest revision as of 12:07, 3 November 2021

Very High colour rendering T8 fluorescent linear lamps TL-D type 90 Graphica

Features

  • Special Halophosphate based coating
  • G3 bi-pin base
  • Color rendering index Ra of 95
  • Typical lifetime of 20.000 to 24.000 hours
  • Luminous efficacy of 61 to 93 lumens/watt
  • Two white appearances (5300 and 6500 K colour temperature)
  • Universal operating position

Lamp control gear

  • Requires external gear and appropriate wiring:
    • Compatible reactive inductive ballast with matching power rating and starter
    • Compatible high-frequency electronic ballast with preheating (preferably)
    • May require power factor correction capacitor for reactive ballasts

Philips TL-D 36W

Best retro purpose

Flourescent lamps are the most popular and widely used lighting source. Still widely used in most indoor environments due to their high efficiency and very good colour reproduction, flourescent lamp stocks and availability is still high. Millions of these lamps have been produced worldwide for decades. They are clearly suited for indoor lighting especially when paired with an electronic ballast that eliminates flicker and also increases system efficiency. Due to the great variety of lamps, there are some suggestions for use. Most flourescent lamps operate well at 25 degrees Celsius ambient temperature and have very low light output in freezing or below freezing environments but hot environments also reduce efficiency.

90 Graphica lamps were specialist items, high-end products that had a highly accurate colour reproduction. They were used in environments such as the printing and publishing business were comparisons and proofing of printed materials was required. These lamps had very low efficiency compared with other flourescent lamps but had a almost unique abilities for professional environments. While these lamps can be used in interior lighting and they showcase everything as is they were light by the sun on a clear day, their lower efficiency, slightly higher luminous flux loss due to aging and limited colour appearance selection make them quite unsuitable for general lighting. 90 Graphica lamps have been manufactured in very low quantities which means that stocks are scarce.

Understanding manufacturer data

Lamp light output is always measured in lumens. This is a way of measuring by averaging light output at a distance of 1 meter in an integrating sphere. This was carried out in lab environments and this information was mentioned in lamp datasheets and catalogues. While this information is accurate it should be considered only across similar lamp types.

Lamp life is presented in thousands of hours. It does not point at a specific moment when an installed lamp will not operate anymore but a statistical point at which some of the lamps may not operate, giving a rough estimate of useful life.

Ra8 colour rendering index, or simply colour rendering index is a way of expressing the typical colour rendering capability of a lamp. While it may be non-intuitive this is a computed average of brightness of certain coloured samples that are light by the lamp. The brighter they are, the more efficient is the lamp in this task. Most lamps do not have a continuous colour spectra so only some specific colours might look very bright and others look very dull. Colour samples are not intense reds, greens and blues but intermediately vivid colours that are focused on human skin colours and some fabrics or surfaces, meaning that a only very high colour rendering indexes are desirable for indoor home lighting. Sun light renders colours almost perfectly, having a value of 100 while typical lamps have a rendering index between 50 and 80, a good value being above 80 and a poor one below 50.

Colour temperature is another important detail. The value is presented in Kelvins and follows a theory that boils down to the fact that light can be produced by heating a metal up to a specific temperature. A camp fire releases light as the flame reaches around 1500-2000 degrees Celsius and a slightly higher value expressed in Kelvin. The designation is warm white for a value of around 2700 Kelvin, natural white with a value of around 3200-3500 Kelvin, cool white for a value of around 4000-4500 Kelvin, daylight for a value between 5000 and 5500 Kelvin, and cool daylight for a value above 6000-6500 Kelvin. There are cultural preferences that make some warm colour temperatures preferred in colder climates and cool colour temperatures in warmer climates. The most popular home lighting worldwide is mostly warm white, due to a comfortable, pleasant atmosphere that is close to the old incandescent lamp.

Technical details

Designation Base Lamp wattage Luminous flux Colour appearance Colour Temperature Colour Rendering Index (Ra8) Life (to 50% failures)
MASTER TL-D 90 Graphica 18W/950 SLV G13 18 W 950 lm Daylight 5300 K 98 20000 hours
MASTER TL-D 90 Graphica 18W/965 SLV G13 18 W 930 lm Cool Daylight 6500 K 98 20000 hours
MASTER TL-D 90 Graphica 36W/950 SLV G13 36 W 2300 lm Daylight 5300 K 98 20000 hours
MASTER TL-D 90 Graphica 36W/965 SLV G13 36 W 2100 lm Cool Daylight 6500 K 98 20000 hours
MASTER TL-D 90 Graphica 58W/950 SLV G13 58 W 3650 lm Daylight 5300 K 98 20000 hours
MASTER TL-D 90 Graphica 58W/965 SLV G13 58 W 3350 lm Cool Daylight 6500 K 98 20000 hours

Durability and Repair-ability

Greatest features & flaws

Features Flaws
Low glare risk, uniform lighting Quite large lamps and fixtures
Moderate efficiency, long life, almost perfect colour rendering Fragile construction
Mostly suited for directional light Sensitive to operating temperature
Quick lamp start and restart, inexpensive Requires lamp gear

Review

The TL-D range was conceived as a complete portfolio which was quite well suited for any task. While commercial lighting was the most successful market, flourescent lamps were present also in residential and industrial environments and they were highly successful. 90 Graphica lamps were up-market products that catered to excellent colour reproduction. Until the advent of advanced LED lamps, flourescent lamps were unsurpassed in terms of efficiency and lighting comfort. The lamp's quick restart, good light stability even on conventional, magnetic gear, and reasonably simple wiring made them easy to service although the lamp bi-pin connection was prone to failure due to lamp's handling as well as normal wear, the system was reasonably easy to repair and failures were quite obvious. The only drawback of these upper market lamps ranges was a slightly higher price than typical TL-D standard lamps and sensitivity to operating temperatures, common to all flourescent lamps. This major drawback seriously limited outdoor applications.

90 Graphica lamps were high-end lamps designed for requirements of niche markets. Their efficiency was much less important than strict adherence to product manufacturing control, stability, and accurate colour reproduction. These lamps are true state-of-the-art products for situations where proofing of printed or on-screen materials is paramount and they were very successful. This product line has existed for more than 20 years and perfectly suited demanding technical requirements but is less suited for home or office environments due to price and scarcity. Low light outputs relative to other lamp types and especially to the Super 80 line seriously limits appeal even if perfect colour reproduction is a major advantage. Keep in mind that no known light source was available until these and compatible lamps from other manufacturers reached a fantastic colour rendering index of 98. Although incandescent and high intensity discharge lamps can get close with filters and special lamp types to accurate daylight reproduction, 90 Graphica lamps are truly unique.

Operation

All lamps require the same lamp gear that can be either conventional, composed of a magnetic, reactive or inductive ballast placed in series with the lamp along with a starter that preheats the lamp's filament to ensure reliable starts and low lamp stress. An electronic lamp gear, preferably with preheating, can be used to increase light output, eliminate flicker and increase the lamp's service life. Note that some cheap electronic ballasts do not actually offer preheating and start instantly the lamp, reducing the lamp's useful life. Preheating of lamps is assumed if there is any mention of a 0.5second duration on the electronic ballast label or the word preheating. Most world manufacturers released electronic control gear and some products even allowed variable dimming using special protocols.

While a dimmed flourescent lamp is not as efficient as full power operation, there were and are some environments were such flexibility is appreciated. Note that starting and operating dimmed lamps is less reliable and the temperature balance and optimum operation conditions slightly deviate in these circumstances. Overpowering a lamp is possible but it is not advised. While Super 80 lamps are best suited for these circumstance that increase light output with some reduction in efficiency and service lamps, operation in such conditions stresses the lamp. Note that operating in cold environments, as a deviation from ideal conditions, reduces lamp current and power, making the lamp slightly unstable and dim.

Suitability

A major advantage of T8 or TL-D lamps, regardless of type, is their full compatibility with systems of similar power ratings that were used with T12 lamps along with full replacement capability of any lamp type at a specific wattage. This makes it possible to test and replace many lamps of a specific wattage even mix lamps in multi-lamp fixtures to create a desired effect. Compatibility of T12 and T8 lamps was very important in the past as new T8 lamps were more efficient and used less power while being fully capable to be retrofitted on old installations.

Closed as well as open fixtures are very well suited for any lamp type. In general, open fixtures are better suited for lamps operating in warmer indoor environments while enclosed fixtures are better suited for colder environments. Despite what any datasheet may suggest, deviating higher or lower than the set 30-35 degrees Celsius lamp temperature slightly reduces efficiency. 90 Graphica lamps are more sensitive to additional light losses due to internal coating's temperature variation.

History

Flourescent lamps were an evolution of clear mercury vapour lamps. Development followed two avenues to increase efficiency, low pressure mercury vapour discharge and high pressure mercury discharge. High pressure mercury discharge created more useful light but the same deficit of no red and orange light was present so the light was still unsatisfactory. Low pressure mercury discharge is very efficient but not in outputting visible light, it is on UV-light emission. This UV-light is useless if it cannot be converted to visible light.

Flourescent powders were developed to convert UV-light into visible light. Some of these powders were capable of emitting light at some wavelengths, making specific colours to be cast around but they had to be quite ressistant to UV-light and efficient. This meant that some time passed until the advent of halophosphate based colours that made possible the first daylight T12 flourescent lamps, around late 1930s. This was a major achievement as such lamps had the capability of directly competing with incandescent lamps and offer better efficiency and longer life.

Subsequent developments improved lamp life and created a wide variety of flourescent powders that cast white light with different colour appearances from warm and neutral to cold and daylight. Higher and lower power lamps were created and standardization established. The preferred lamp gear turned from incandescent ballasting or mixed light to magnetic or reactive ballasts, which improved system efficiency. In the late 1970s, following requirements for higher energy efficiency due to the world oil crisis of 1973, there were major advances in technology.

The advent of high efficiency tri-band or tri-phosphorous lamps was the most important landmark. Successful development of flourescent powders that had peak UV to visible light conversion at blue, red, and green colours with peaks near the ideal wavelengths made it possible to release lamps with specific colour appearances. This high energy in light conversion was complemented by changes in the lamps gas's fill from argon to Krypton, reducing thermal losses with a slight increase in operating voltage and starting voltage. This was the market releases of the the highly successful T8 lamp, or TL-D lamp that dominated since the early 90s. Of course, up until this time there were improvements in cathodes design and electron emmissive coatings as well as other performance enhancing solutions but the release of the TL-D lamp was the most important moment.

Production of specialist lamps started in the 1950s with coloured lamps but also expanded to include De Luxe and specific lamps that would cater for many purposes. De Luxe lamps were an improvement of standard lamps in terms of colour reproduction but was less efficient and had shorter service life due to coatings that were less stable in time than standard lamps. Graphica lamps were a slight adaptation of previously developed phosphorus to TL-D lamps and their gas's fill and some experimentation in improving other aspects of operation to achieve better performance.

Manufacturing specificities

Philips flourescent lamps had very good manufacturing tolerances and the lamp's construction along with flourescent powder quality made reliable, predictable operation entirely ensured. Other world manufacturers were capable of similar performance. However, some slight differences were noticeable. For instance, Philips had slightly less powerful red phosphorus than Osram, which means that entirely equivalent lamps from both manufacturers had slightly different colour appearance. On the other side, Chinese branded lamps were much inferior in terms of flourescent powder quality and colour reproduction as well as efficiency and service life.