Standard Metal Hallide Lamp for indoor and outdoor lighting with 250W and 400W (E40 base), clear tubular bulb
High colour rendering T8 fluorescent linear lamps TL-D type Super 80, 90 De Luxe, 90 Graphica


== Features ==
== Features ==
*Clear tubular outer bulb
*Triphosphor internal coating outer bulb (Super 80 lamps)
*Internal high pressure quartz discharge tube
*Triphosphor internal coating and additional coating (TL-D 90 De Luxe)
*E40 base
*Special Halophosphate based coating (90 Graphica lamps)
*Color rendering index Ra of 65
*Bi-pin base
*Color rendering index Ra of 80 to 95
*Typical lifetime of 20.000 to 24.000 hours
*Typical lifetime of 20.000 to 24.000 hours
*Luminous efficacy of 84 to 89 lumens/watt
*Luminous efficacy of 61 to 93 lumens/watt
*Cool white or daylight colour designation (4500 or 6700 K colour temperature)
*Most colour designations (from 2700 to 6500 K colour temperature)
*Horizontal operating position
*Universal operating position


== Lamp control gear ==
== Lamp control gear ==
*Requires external gear (similar to mercury vapour lamps) and appropriate wiring:
*Requires external gear and appropriate wiring:
** Philips BHL or compatible reactive inductive ballast with matching power rating
** Compatible reactive inductive ballast with matching power rating and starter
** Philips SI or compatible parallel ignitor for 5000 Volt pulses
** Compatible high-frequency electronic ballast with preheating (preferably)
** May require power factor correction capacitor for balancing line load
** May require power factor correction capacitor for reactive ballasts


|style="vertical-align:top" |
|style="vertical-align:top" |
Line 27: Line 28:


== Best retro purpose ==
== Best retro purpose ==
Flourescent lamps are the most popular and widely used lighting source. Still widely used in most indoor environments due to their high effciency and very good colour reproduction, flourescent lamp stocks and availability is still high. Millions of these lamps have been produced worldwide for decades. They are clearly suited for indoor lighting especially when paired with an electronic ballast that eliminates flicker and also increases system efficiency. Due to the great variety of lamps, there are some suggestions for use. Most flourescent lamps operate well at 25 degrees Celsius ambient temperature and have very low light output in freezing or below freezing environments but hot environments also reduce efficiency.
Super 80 lamps have been the most popular lamp type since the early 2000s and up to the present (2021). They may still be found new, are cheap and have very good performance. This lamp type is especially suited for areas that require a large amount of light. Due to the lamp's size and luminous flux, they are best suited for floodlighting although they can be just as well used for general lighting in any conditions. These lamps have a tendency of over saturating objects colour appearance which may be a desired or undesired side effect. Any interior can be well and pleasantly light with these lamps although foliage, plants, flowers are very well showcased.
90 De Luxe lamps have balanced, good colour reproduction with a slight efficiency reduction compared with Super 80 lamps. Due to their slightly higher sale price and slightly lower luminous flux, they were significantly less popular than Super 80 lamps. The major benefits of these lamps is that colour reproduction is very close to natural light, offering a highly realistic perspective on the environments. 90 De Luxe lamps can showcase fine goods, furniture, creating a pleasant, comfortable atmosphere in offices, living and dining rooms, bedrooms.
90 Graphica lamps were specialist items, high-end products that had a highly accurate colour reproduction. They were used in environments such as the printing and publishing business were comparisons and proofing of printed materials was required. These lamps had very low efficiency compared with other flourescent lamps but had a almost unique abilities for professional environments. While these lamps can be used in interior lighting and they showcase everything as is they were light by the sun on a clear day, their lower efficiency, slightly higher luminous flux loss due to aging and limited colour appearance selection make them quite unsuitable for general lighting. 90 Graphica lamps have been manufactured in very low quantities which means that stocks are scarce.


== Understanding manufacturer data ==  
== Understanding manufacturer data ==  
Line 61: Line 69:
! Features !! Flaws  
! Features !! Flaws  
|-
|-
| High light output in very compact package || Serious glare risk
| Low glare risk, uniform lighting || Quite large lamps and fixtures
|-
|-
| High efficiency, long life, average colour rendering || Quite expensive lamps
| High efficiency, long life, very good colour rendering || Fragile construction
|-
|-
| Mostly omni-directional light || Sensitive to operating position and unbalanced wearing
| Mostly suited for directional light || Sensitive to operating temperature
|-
|-
| Quick lamp start || Slow restart, requires bulky, heavy, complex lamp gear
| Quick lamp start and restart, inexpensive || Requires lamp gear
|}
|}


== Review ==
== Review ==
The TL-D range was conceived as a complete portfolio which was quite well suited for any task. While commercial lighting was the most successful market, flourescent lamps were present also in residential and industrial environments and they were highly successful. Super 80, 90 De luxe and 90 Graphica lamps were up-market products that catered to efficiency as well as good colour reproduction. Until the advent of advanced LED lamps, flourescent lamps were unsurpassed in terms of efficiency and lighting comfort. The lamp's quick restart, good light stability even on conventional, magnetic gear, and reasonably simple wiring made them easy to service although the lamp bi-pin connection was prone to failure due to lamp's handling as well as normal wear, the system was reasonably easy to repair and failures were quite obvious. The only drawback of these upper market lamps ranges was a slightly higher price than typical TL-D standard lamps and sensitivity to operating temperatures, common to all flourescent lamps. This major drawback seriously limited outdoor applications.
Super 80 lamps were advantageous due to high luminous output and low price. The wide array of colour temperatures caters to any application. Warm colours or more active daylight ambiances can be created easily. The lamps' very good stability and output ensures a long service life with minimal degradation. This was especially important compared with TL-D Standard lamps, as the older lamp type aged much quicker and had lower light output along with colour reproduction. Requirements for higher than 80 Ra colour rendering index in Europe made the lamps extremely popular and even made them as cheap or even cheaper than TL-D standard lamps due to volumes, marketing and economies of scale. This 1980's lamp had a massive impact in late 90s and early 2000s as most indoor environments became light as such.
90 De Luxe lamps were very good flourescent lamps. Combining the efficiency of Super 80 lamps with the uniform spectrum allowed by certain technologies developed for TL-D standard lamps made the 90 De Luxe lamps a near high-end choice. With very good colour reproduction, quite high system efficiency and comfortable light with similar colour appearance choices as with Super 80 and standard TL-D lamps, 90 De Luxe lamps were offering major benefits in lighting unsurpassed by previous technologies. Although De Luxe lamps were developed in late 70s they suffered from reduced system efficiency and higher price which limited their market attractiveness. The new 90 De Luxe lamps offered good enough energy efficiency and light output to be competitive which meant that these flourescent lamps started to be more successful. However, their slightly higher cost and wide availability of Super 80 lamps made 90 De Luxe lamps a quite rare presence except in more demanding commercial and residential applications.
90 Graphica lamps were high-end lamps designed for requirements of niche markets. Their efficiency was much less important than strict adherence to product manufacturing control, stability, and accurate colour reproduction. These lamps are true state-of-the-art products for situations where proofing of printed or on-screen materials is paramount and they were very successful. This product line has existed for more than 20 years and perfectly suited demanding technical requirements but is less suited for home or office environments due to price and scarcity. Low light outputs relative to other lamp types and especially to the Super 80 line seriously limits appeal even if perfect colour reproduction is a major advantage. Keep in mind that no known light source was available until these and compatible lamps from other manufacturers reached a fantastic colour rendering index of 98. Although incandescent and high intensity discharge lamps can get close with filters and special lamp types to accurate daylight reproduction, 90 Graphica lamps are truly unique.


== Operation ==  
== Operation ==  
All lamps require the same lamp gear that can be either conventional, composed of a magnetic, reactive or inductive ballast placed in series with the lamp along with a starter that preheats the lamp's filament to ensure reliable starts and low lamp stress. An electronic lamp gear, preferably with preheating, can be used to increase light output, eliminate flicker and increase the lamp's service life. Note that some cheap electronic ballasts do not actually offer preheating and start instantly the lamp, reducing the lamp's useful life. Preheating of lamps is assumed if there is any mention of a 0.5second duration on the electronic ballast label or the word preheating. Most world manufacturers released electronic control gear and some products even allowed variable dimming using special protocols.
While a dimmed flouresecent lamp is not as efficient as full power operation, there were and are some environments were such flexibility is appreciated. Note that starting and operating dimmed lamps is less reliable and the temperature balance and optimum operation conditions slightly deviate in these circumstances. Overpowering a lamp is possible but it is not advised. While Super 80 lamps are best suited for these circumstance that increase light output with some reduction in efficiency and service lamps, operation in such conditions stresses the lamp. Note that operating in cold environments, as a deviation from ideal conditions, reduces lamp current and power, making the lamp slightly unstable and dim.


== Suitability ==  
== Suitability ==  
A major advantage of T8 and TL-D lamps, regardless of type, is their full compatibility with systems of similar power ratings that were used with T12 lamps along with full replacement capability of any lamp type at a specific wattage. This makes it possible to test and replace many lamps of a specific wattage even mix lamps in multi-lamp fixtures to create a desired effect. Compatibility of T12 and T8 lamps was very important in the past as new T8 lamps were more efficient and used less power while being fully capable to be retrofitted on old installations.
Closed as well as open fixtures are very well suited for any lamp type. In general, open fixtures are better suited for lamps operating in warmer indoor environments while enclosed fixtures are better suited for colder environments. Despite what any datasheet may suggest, deviating higher or lower than the set 30-35 degrees Celsius lamp temperature slightly reduces efficiency. Super 80 lamps are the least affected by temperature changes as only the internal UV radiation can be influenced. 90 De Luxe and especially 90 Graphica lamps are more sensitive to additional light losses due to internal coating's temperature variation.


== History ==
== History ==


== Manufacturing specificities ==
== Manufacturing specificities ==
Philips flourescent lamps had very good manufacturing tolerances and the lamp's construction along with flourescent powder quality made reliable, predictable operation entirely ensured. Other world manufacturers were capable of similar performance. However, some slight differences were noticeable. For instance, Philips had slightly less powerful red phosporus than Osram, which means that entirely equivalent lamps from both manufacturers had slightly different colour appearance. On the other side, Chinese branded lamps were much inferior in terms of flourescent powder quality and colour reproduction as well as efficiency and service life.