*Typical lifetime of 12.000 to 15.000 hours | *Typical lifetime of 12.000 to 15.000 hours | ||
*Luminous efficacy of 46 to 65 lumens/watt | *Luminous efficacy of 46 to 65 lumens/watt | ||
* | *Three colour appearances (2700, 4000 and 6500 K colour temperature) | ||
*Universal operating position | *Universal operating position | ||
| Line 81: | Line 81: | ||
== Durability and Repair-ability == | == Durability and Repair-ability == | ||
Due to their | Due to their construction, these lamps are not serviceable in the true sense. Despite the lamp's pro designation, the lamp itself cannot be plugged in and out of the base, to allow simple replacements. While some board repairs can be done if the ballast experiences failure, the most likely cause is the lamp itself burning out, meaning that fillaments are so damaged that the lamp behaves erratically or does not work at all. While fillaments can be joined to allow forced lamp starting, this solution poses risk of catastrophic failure of the internal ballast so it is not recommended. | ||
Overall, these lamps were at least twice if not | Generally, MASTER PL-Electronic lamps are much more worn out by the time they cease to function so there is very little useful life left for it. The lamp's ballast is quite difficult to access, involving potential partial destruction of the lamp's plastic housing. Overall, these lamps were at least twice if not more, long lived than typical economy compact fluorescent lamps such as the Philips Genie lamp range. However, operation in enclosed fixtures was still the biggest premature failure cause due to the high stress posed by high temperature operation, mainly in the case of the internal ballast components. | ||
== Greatest features & flaws == | == Greatest features & flaws == | ||
| Line 96: | Line 96: | ||
| Mostly suited for accent lighting || Poor lamp service life in enclosed fixtures | | Mostly suited for accent lighting || Poor lamp service life in enclosed fixtures | ||
|- | |- | ||
| Quick lamp start and restart | | Quick lamp start and restart || Fragile construction, somewhat expensive | ||
|} | |} | ||
== Review == | == Review == | ||
The Master PL-Electronic range was marketed as an improvement of the economy compact flourescent lamp range, offering longer service lifetime. Unfortunately, these lamps were not professional in the true sense of the word, as the lamp and ballast could not be easily replaced when needed and there was no major improvement in light appearance or colour rendering compared with cheaper lamps. Another minor advantage was better performance due to less impact of frequent switching on light output and lamp life. However, light uniformity is reduced downwards due to the lamp's shape | The Master PL-Electronic range was marketed as an improvement of the economy compact flourescent lamp range, offering longer service lifetime. Unfortunately, these lamps were not professional in the true sense of the word, as the lamp and ballast could not be easily replaced when needed and there was no major improvement in light appearance or colour rendering compared with cheaper lamps. Another minor advantage was better performance due to less impact of frequent switching on light output and lamp life. However, light uniformity is reduced downwards due to the lamp's shape. | ||
Theoretically, these lamps could operate better in hotter and colder environments due to better lamp design but this was not as important in most use case scenarios. Master PL-Electronic lamps mostly replaced incandescent lamps with the goal of major energy savings in hospitality and restaurant applications were cost and simplicity were valued more. On these grounds, the lamp fared well but there was nothing special about it. Ultimately, it was and still is a cheap lamp that has no redeeming quality and can be easily replaced with a modern LED lamp. | Theoretically, these lamps could operate better in hotter and colder environments due to better lamp design but this was not as important in most use case scenarios. Master PL-Electronic lamps mostly replaced incandescent lamps with the goal of major energy savings in hospitality and restaurant applications were cost and simplicity were valued more. On these grounds, the lamp fared well but there was nothing special about it. Ultimately, despite the higher marketing price, it was and still is a cheap lamp that has no redeeming quality and can be easily replaced with a modern LED lamp. It is slightly more fashionable than the low cost Genie E-Saver lamp, in case design is really taken into account. | ||
== Operation == | == Operation == | ||
| Line 115: | Line 115: | ||
While this lamp generally folows the typical progress of flourescent light sources, there is one major feature that was specific to this range. In late 1980s, a compact flourescent lamp was designed, the venerable SL. It was the first product to use a magnetic ballast and starter that were integrated into a rather bulky base. The lamp had a noticeable hum and flicker but it brought major advantages in terms of energy efficiency in replacing typical incandescent lamps. In the 1990s, compact lamps received an improved electronic ballast that improved lamp's efficiency and lifetime, with no visible flicker. This development lead to later mass market popularity of compact fluorescent lamps, as they were more compact and slightly more pleasant to use. Of course, there was also a downside. Philips noticed that lamp replacements at the end of their useful life was not popular due to the typical user mindset so Philips did not bother to create, from that point further, lamps that had separate bases and lamps, reducing user mistakes upon replacement. | While this lamp generally folows the typical progress of flourescent light sources, there is one major feature that was specific to this range. In late 1980s, a compact flourescent lamp was designed, the venerable SL. It was the first product to use a magnetic ballast and starter that were integrated into a rather bulky base. The lamp had a noticeable hum and flicker but it brought major advantages in terms of energy efficiency in replacing typical incandescent lamps. In the 1990s, compact lamps received an improved electronic ballast that improved lamp's efficiency and lifetime, with no visible flicker. This development lead to later mass market popularity of compact fluorescent lamps, as they were more compact and slightly more pleasant to use. Of course, there was also a downside. Philips noticed that lamp replacements at the end of their useful life was not popular due to the typical user mindset so Philips did not bother to create, from that point further, lamps that had separate bases and lamps, reducing user mistakes upon replacement. | ||
As all compact fluorescent lamps were ultimately an economy prospect to replace consumer's incandescent lamps, price was always an important factor. Improvements in the PL-Electronic lamps centered on better designed electronic ballasts that could have higher rated components, able to better survive increased environment temperatures of enclosed fixtures, and improved lamp tube design that reduced impact of temperature variations. | As all compact fluorescent lamps were ultimately an economy prospect to replace consumer's incandescent lamps, price was always an important factor. Improvements in the PL-Electronic lamps centered on better designed electronic ballasts that could have higher rated components, able to better survive increased environment temperatures of enclosed fixtures, and improved lamp tube design that reduced impact of temperature variations. The compact fluorescent lamp market was increasing up until the early 2000s, when most incandescent fixtures were replaced, and it slowly declined with the transition towards led lighting. The worldwide incandescent bulb ban had a major impact in increasing sales but in a slightly different way: users simply purchased lower quality bulbs or cheaper integrated compact flourescent lamps, meaning that there was no improvement on the standard Genie lamps or PL-Electronic. | ||
The compact fluorescent lamp market was increasing up until the early 2000s, when most incandescent fixtures were replaced, and it slowly declined with the transition towards led lighting. The worldwide incandescent bulb ban had a major impact in increasing sales but in a slightly different way: users simply purchased lower quality bulbs or cheaper integrated compact flourescent lamps, meaning that there was no improvement on the standard Genie lamps or PL-Electronic. | |||